Each roll brace shall be a joist or blocking matching the depth of the edge member and extending perpendicular to the edge member a minimum of 16 inches (406 mm) from the edge. Blocking shall have end connections with a minimum of six (6) – 16d common nails. Floor sheathing shall be continuous for a minimum of 24 inches (610 mm) from the edge and shall be fastened to each roll brace with a minimum of twelve (12) – 10d common nails and shall be fastened to the edge member with a minimum of twelve (12) – 10d common nails within 12 inches (305 mm) of the roll brace.
R502.11.3 Roll bracing
By Delon Shetler|2026-03-31T08:49:24-04:00March 18, 2026|VI CODE 2024, VI CODE APP|Comments Off on R502.11.3 Roll bracing